Figure 30 a standard stall.
Handicap bathroom door size.
The required minimum floor space for a handicapped accessible bathroom is 30 inches by 48 inches.
However as long as there was enough room for the knees and legs of people in wheelchairs.
The americans with disabilities act ada of 1990 includes specific guidelines for the construction of accessible or ada compliant bathrooms.
Doorways should be at least 32 inches wide with the door open at 90 degrees.
They can also serve as a general guide for safe user friendly accessible design when ada compliance is not required.
You can place part of the area under the equipment.
Handicap bathroom ideas can provide advanced or parallel access to bathroom equipment.
If toilet stall approach is from the latch side of the stall door clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in 1065 mm.
According to the ada an accessible bathroom should meet the following size criteria.
The width of a doorway inside a building that you frequently visit is a measurement that is hardly ever brought up or talked about.
For commercial bathrooms with multiple toilet stalls and handicap the rules change a little.
30 inches by 48 inches from the door to the sink at least 60 inches around the side and 56 inches from the rear so a wheelchair can turn around with ease.
Multiple toilet stall layouts.
These design requirements must be met for most public and commercial bathrooms.
For your information this type of bathroom requires a minimum floor size of 30 inches 48 inches.
In a corner handicap stalls require a minimum of 60 x 60 compartment and is required with a minimum door size of 32 and the maximum size and more common is the 36 door.
To meet the ada accessibility standard doors must have a clear width of 32 inches from the face of the door to the opposite stop.
To ensure compliance with ada door clearance requirements doors should open with minimal force and have handles that are easy to grab with one hand.
The space can provide forward or parallel access to the bathroom equipment and part of the area can underneath the equipment as long as there is enough clearance for the knees and toes of the person in the wheelchair.
An example of a single ada bathroom layout.
The minimum width of the stall is 60 inches 1525 mm.